European box transformer

Description:

European box substation is a high-voltage switch set, distribution transformer and low-voltage distribution device in three different compartments, and electrical connections are realized through cables or busbars. The high- and low-voltage distribution devices and transformers used are Regular styling products. The intelligent prefabricated substation series can combine high-voltage switchgear (RM6 or SFG, domestic load switches with electric remote automatic control devices), transformers, low-voltage distribution settings, low-voltage smart switches, and automatic reactive power compensation according to a certain wiring plan Integrated into one, it has the functions of remote control, telemetry, telemetry, remote adjustment and other functions for local or remote operation.
Quote Now

[contact-form-7 id=”125″ title=”Contact Form”]

Description

YBM prefabricated substation (European box transformer)

European box substation is a high-voltage switch set, distribution transformer and low-voltage distribution device in three different compartments, and electrical connections are realized through cables or busbars. The high- and low-voltage distribution devices and transformers used are Regular styling products. The intelligent prefabricated substation series can combine high-voltage switchgear (RM6 or SFG, domestic load switches with electric remote automatic control devices), transformers, low-voltage distribution settings, low-voltage smart switches, and automatic reactive power compensation according to a certain wiring plan Integrated into one, it has the functions of remote control, telemetry, telemetry, remote adjustment and other functions for local or remote operation. It is suitable for public distribution networks with rated voltage of 24KV and below, rated frequency of 50Hz three-phase AC system and capacity of 2500kVA and below, residential communities, factories and mines, large construction sites, high-rise buildings, airport terminals and other areas with ring network and terminal power supply. Temporary facilities, etc.

 

When you need to place an order, what parameters do you need to provide?

Transformer model, specification, wiring group

High and low voltage main wiring diagram and main electrical component model parameters

Should the load switch be equipped with an electric operating mechanism?

Incoming cable cross-section

Please submit special requirements to the manufacturer

 

Technical parameter

Item unit parameter
High voltage section Rated frequency Hz
Rated voltage KV 20 10
Max working voltage KV 24 12
Operating withstand voltage to ground and phase/isolation interface KV 65/79 42/48
Lightning impulse withstand voltage to ground and phase/isolation fracture KV 125/145 75/85
Low voltage section Rated current A 400 630
Rated short-time withstand current KA 16(28) 20(2S)
Rated peak withstand current KA 40 50
Transformer part Rated voltage V 380 220
Main circuit rated current A 100~4000
Rated short-time withstand current KA 15              ~           50
Rated peak withstand current KA 20              ~          105
Branch current A 10-800
Number of branch circuits road 1-12
Compensation capacity Kvar 0-360
Rated Capacity KVA 50~2500
Impedance voltage % 4.5 6(dry)
Tap range ±2×2.5% ±5%
Group Yyn0 Dyn11